BSC 12

Description

  • Features:
    • 1″ high resolution display Touch screen optional
    • User customized NIBP measuring cycles up to 5-phase
    • Versatile clinical calculations for application convenience
    • 9 traces on-screen waveforms and maximal up to 13
    • Data export and software upgrade
    • HL7 protocol, Bed to bed view and 12-lead ECG available

    ECG

    • Input dynamic range: ±(0.5mVp~5mVp)
    • Differential input impedance: ≥10MΩ
    • Bandwidth: 0.05~150Hz (Diagnostic)
    • 5~40Hz (Monitoring)
    • 1~20Hz (Operation)
    • CMRR: ≥90dB (Diagnostic) ≥105dB (Monitoring & Operation)
    • Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
    • Sweeping speed: 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s
    • HR measuring range: 15~350bpm
    • HR accuracy: ±1% or ±2bpm, whichever is greate Pacemaker pulse detection and rejection function

    RESP

    • Measuring range: 0~120rpm
    • Measuring accuracy: ±5% or ±2 rpm, whichever is greater

    TEMP

    • Measuring range: 21.0~50.0°C
    • Measuring accuracy: ±0.2°Cfrom 25~45°C

    NIBP  

    • Technique: Oscillometric method
    • Typical measurement time: <30 seconds (adult cuff) SYS: 40~275mmHg (Adult)
    • NIBP measuring range: 40~200mmHg (Pediatric) 40~135mmHg (Neonate)
    • DIA: 10~210mmHg (Adult)
    • NIBP measuring range: 10~150mmHg (Pediatric) 10~95mmHg (Neonate)
    • MAP: 20~230mmHg (Adult)
    • NIBP measuring range: 20~165mmHg (Pediatric)
    • 20~110mmHg (Neonate)
    • NIBP measuring accuracy: Mean difference: ±5mmHg
    • Standard deviation: 8mmHg
    • NIBP measurement mode: Manual, Auto, STAT, Multi-cycle mode
    • Auto measuring intervals: 1-480min

     

     

    SpO2

    • Technique: Dual-wavelength optical method
    • Measuring range: 0%~100%
    • Measuring accuracy: Arms is not greater than 2% for SpO2 range 70~100%.
    • PR measuring range: 30~250bpm
    • PR measuring accuracy: ±2bpm or ±2%, whichever is greater
    • Low perfusion performance: As low as 0.3%.

    CO2

    • Technique: Infrared optical method
    • Sampling mode: Sidestream or Mainstream
    • Measuring range: 0~150mmHg
    • Measuring accuracy:
    • 0~40mmHg ±2mmHg
    • 41~70mmHg ±5% of reading
    • 71~100mmHg ±8% of reading
    • 101~150mmHg ±10% of reading
    • Flow rate: 50ml/min ±10 ml/min (Sidestream)

    Cerebral State Monitoring (CSM)

    • EEG sensitivity: ±400µV
    • Noise level: <2µVp-p, <0.4µV rms (1~250Hz)
    • CMRR: >140dB
    • Input impedance: >50Mohm
    • CSI and update: 0-100. filter: 6-42Hz, 1 sec. update
    • EMG%: 0-100 (logarithmic)
    • filter: 75-85 Hz, 1 sec. update.
    • BS%: 0-100. filter: 2-42 Hz, 1 sec. update

    IBP

    • Technique: Strain gauge transducer
    • Input sensitivity: 5µV/V/mmHg
    • Measuring range: -50~300mmHg
    • Measuring accuracy: ±2% or ±4mmHg, whichever is greater
    • Measuring positions: ART, RAP, PA, LAP, CVP
    • ICP, AUXP1, AUXP2
    • Calibration: zero calibrating

    Cardiac Output (C.O.)

    • Blood temperature
    • measuring: range: 23-43℃, accuracy: ±0.5℃
    • Injecta temperature
    • measuring: range: 0-20℃, accuracy: ±0.5℃
    • Measuring range: 0.2~20 L/min
    • Measuring accuracy: ±0.2 L/min or ±10%, whichever is greater

    Other Specifications

    • Power supply: AC 100V-240V, 50/60Hz, 60VA
    • Built-in lithium battery: 11.1V/4400mAh
    • Display: 12.1 inch TFT display
    • Alarming method: 3 levels audible-visible alarm
    • Networking: Ethernet

    Standard configuration: ECG, Respiration, SpO2, PR, NIBP, Temperature.

    Options: 2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG Cardiac Output, Cerebral State Monitoring, CMS, Touch Screen.

     

    Quality Standard: US-FDA Certified.